• AEC-Q100 Qualified With the Following Results:
Device temperature Grade1:-40~125 ℃ ambient operating temperature range
• Single-Channel Constant-Current LED Driver With PWM Dimming
• Wide Input-Voltage Range: 4.5V ~40V
• Constant Output Current, Adjustable by Sense Resistor
• Precision Current Regulation, Tolerance ±4.6%
• Maximum Current: 300mA
• Heat Sharing With External Resistor
• Low Dropout Voltage (Current-Sense Voltage Drop Included)
Maximum Dropout: 400mV at 70mA
Maximum Dropout: 1.3V at 300mA
• Diagnostics and Protection
LED Open-Circuit and Short-Circuit Detection With Auto-Recovery
Diagnostic-Enable With Adjustable Threshold for Low-Dropout Operation
Fault Bus up to 15 Devices, Configurable As Either One-Fails–All-Fail or Only-Failed-Channel Off
Low Quiescent Current and Fault-Mode Current (<250 µA per Device)
• Qualified for Automotive Applications
• AEC-Q100 Qualified With the Following Results:
Temperature Grade 1: –40°C to 125°C Ambient Operating Temperature Range
Device HBM ESD Classification Level H2
Device CDM ESD Classification Level C3B
Documentation available to aid functional safety system design
• Single-Channel Constant-Current LED Driver With PWM Dimming
• Wide Input-Voltage Range: 4.5 V–40 V
• Constant Output Current, Adjustable by Sense Resistor
• Precision Current Regulation, Tolerance ±4.6%
•• Maximum Current: 300 mA
• Heat Sharing With External Resistor
• Low Dropout Voltage (Current-Sense Voltage Drop Included)
Maximum Dropout: 150 mV at 10 mA
Maximum Dropout: 400 mV at 70 mA
Maximum Dropout: 700 mV at 150 mA
Maximum Dropout: 1.3 V at 300 mA
• Diagnostics and Protection
LED Open-Circuit and Short-Circuit Detection With Auto-Recovery
Diagnostic-Enable With Adjustable Threshold for Low-Dropout Operation
Fault Bus up to 15 Devices, Configurable As Either One-Fails–All-Fail or Only-Failed-Channel Off
Low Quiescent Current and Fault-Mode Current (<250 µA per Device)
• Operating Junction Temperature Range: –40°C to 150°C